Technologija |
Standartai |
IEEE 802.3 10Base-T Ethernet; IEEE 802.3u 100Base-TX Fast Ethernet; IEEE802.3x Flow Control and Back-pressure; IEEE 802.3af Power Over Ethernet |
IEEE 802.3 10Base-T Ethernet; IEEE 802.3u 100Base-TX Fast Ethernet; IEEE 802.3u 100Base-FX Fast Ethernet Fiber; IEEE802.3x Flow Control and Back-pressure; IEEE 802.3af Power over Ethernet |
IEEE 802.3 10Base-T Ethernet, IEEE 802.3u 100Base-TX Fast Ethernet, IEEE 802.3ab 1000Base-T, IEEE802.3x Flow Control and Back-pressure, IEEE 802.3af Power Over Ethernet, IEEE 802.1p Class of Service |
IEEE 802.3 10Base-T Ethernet; IEEE 802.3u 100Base-T Fast Ethernet; IEEE 802.3ab 1000Base-T; IEEE802.3x Flow Control and Back-pressure; IEEE 802.3af Power Over Ethernet; IEEE 802.1p Class of Service |
IEEE802.3 10Base-T; IEEE 802.3u 100Base-T Fast Ethernet; IEEE 802.3ab 1000Base-T; IEEE802.3x Flow Control and Back-pressure; IEEE 802.3af Power Over Ethernet; IEEE 802.1p Class of Service; |
Sąsajos |
Optinis siųstuvas (Vienmodis) |
|
max atstumas 30 KM, min Tx galia: -15 dBm, max Tx galia: -8 dBm, jautrumas: - 34 dBm |
|
|
|
Optinės jungtis |
|
SC (daugiamodė): 50/125um arba 62.5/125um; SC (vienmodė): 9/125um |
|
|
|
Optinis siųstuvas (Daugiamodis) |
|
max atstumas 2 KM, min TX galia: -19 dBm, max Tx galia: -14 dBm, jautrumas: -31 dBm |
|
|
|
Optinis portas |
|
1 x 100 Base-FX |
802.3af compliant PoE ports x 8 10/100/1000Base-TX x 2 Auto MDI/MDI-X, |
|
|
Portų skaičius |
5 x RJ45, Auto MDI/MDI-X |
4 x 10/100 Base-TX, Auto MDI/MDI-X, |
|
4 x 10/100 TX PoE; 2 x 10/100/1000TX |
8 x 10/100 TX PoE; 2 x 10/100/1000TX; |
PoE technologija |
PoE porto įtampa |
nuo 44 iki 57V DC |
44 to 57VDC |
48V / 65W |
DC 48V |
DC 48V |
PoE portai |
Perduodama galia iki 15.4W |
15.4 W |
|
15,4 W |
15,4 W |
Funkcijos |
DIP jungikliai |
Jungiklis 1~5: Pranešimų apie 1~5 sąsajų sujungimo praradimą Įjungimas/Išjungimas Jungiklis 6: Maitinimo klaidos pranešimai Įjungta/Išjungta. |
|
|
- |
- |
Pranešimai apie įvykius |
Sausas relinis kontaktas sąsajų ir maitinimo įvykiams pranešti |
|
|
"Sausas" relinis išėjimas su 1A@24V galimybe |
"Sausas" relinis išėjimas su 1A@24V galimybe |
Maitinimas |
Vartojama galia |
6,5W be PoE, 70W maksimalia apkrovus PoE sąsajas |
6,5W be PoE, 70W su PoE |
7W@DC 48V without PD loading |
8W be PoE; 80W su PoE |
9W be PoE; 166W su PoE; |
Maitinimas |
48V DC |
48VDC (46-57VDC), dubliuotas įėjimas |
48V |
12~24V |
12~24V |
Mechaniniai parametrai |
Išmatavimai |
33.8 mm (Aukštis) x 164.8 mm (plotis) x 108 mm (Ilgis) |
33.8 mm (A) x 164.8 mm(P) x 108 mm (I) |
66(W) x 149(H) x 131.2(D) mm |
66(W) x 149(H) x 131.2(D) mm |
66(W) x 149(H) x 120.5(D) mm |
Korpusas |
IP31 apsaugos klasės, aliuminis |
Aliuminis, IP31 apsaugos klasės |
Rugged Aluminum Alloy Chassis |
Aliuminis |
IP31 apsaugos klasės, aliuminis |
Montavimas |
DIN bėgelis arba ant sienos |
Tvirtiniamas prie sienos arba DIN bėgelios |
DIN-Rail |
DIN bėgelis |
DIN bėgelis |
Aplinka |
Darbo temperatūra |
-20 ~ 70 °C |
-10 ~ 70°C |
|
-25 ~ 60°C |
-25 ~ 60°C |
Sertifikatai |
Laisvas kritimas |
|
IEC 60068-2-32 |
IEC 60068-2-32 |
|
|
Vibracija |
|
IEC 60068-2-6 |
IEC 60068-2-6 |
|
|
Šokas |
|
IEC 60068-2-27 |
IEC 60068-2-27 |
|
|
EMC |
|
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11 |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11 |
|
|
EMI |
|
FCC Class A, EN55022 Class A |
FCC Class A, EN55022 Class A |
|
|
Garantija |
5 metai |
5 metai |
|
5 metai |
5 metai |
|
|
|
|
|
|
Technologija |
Standartai |
IEEE 802.3 10Base-T Ethernet; IEEE 802.3u 100Base-TX Fast Ethernet; IEEE802.3u 100 Base- Fx; IEEE802.3z 1000 Base-Fx; IEEE802.3x Flow Control and Back-pressure; IEEE 802.3af Power Over Ethernet; IEEE 802.1p Class of Service |
IEEE 802.3 10Base-T; IEEE 802.3u 100Base-TX; IEEE 802.3u 100Base-FX; IEEE 802.3ab 1000Base-T; IEEE 802.3z Gigabit Ethernet Fiber; IEEE 802.3af Power over Ethernet; IEEE 802.3at High Power PoE with 2-Event classification; IEEE 802.3x flow control and back pressure |
IEEE 802.3 10Base-T; IEEE 802.3u 100Base-T; IEEE 802.1p Class of Service; IEEE 802.3af Power Over Ethernet(PoE); IEEE 802.3at High Power PoE; IEEE 802.3 Flow Control and Back-pressure; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Spanning Tree |
IEEE 802.3 10Base-T; IEEE 802.3u 100Base-T; IEEE 802.1p Class of Service; IEEE 802.3af Power Over Ethernet(PoE); IEEE 802.3at High Power PoE; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Spanning Tree |
IEEE 802.3 10 Base-T Ethernet IEEE 802.3u 100 Base-TX Fast Ethernet IEEE 802.3u 100 Base-FX Fast Ethernet Fiber IEEE 802.3ab 1000 Base-T IEEE 802.3z Gigabit Fiber IEEE 802.3x Flow Control and Back-pressure IEEE 802.3af Power over Ethernet IEEE 802.3at High power Power over Ethernet IEEE 802.1AB Link Layer Discovery Protocol (LLDP) IEEE 802.1p Class of Service (CoS) IEEE 802.1Q VLAN and GVRP IEEE 802.1QinQ IEEE 802.1D-2004 Rapid Spanning Tree Protocol (RSTP) IEEE 802.1s Multiple Spanning Tree Protocol (MSTP) IEEE 802.3ad Link Aggregation Protocol (LACP) IEEE 802.1x Port Based Network Access Protocol IEEE 1588 Precision Time Protocol |
Sąsajos |
Optinis portas |
|
|
|
JetNet4706f-m, Multi-mode: 2KM max. distance Wave-length: 1310nm Min Tx Power:-19dBm Max Tx Power:-14dBm Min Rx Sensitivity:-30dBm Link budget:11dBm JetNet 4706f-s, Single-mode: 30KM max. distance Wave-length:1310nm Max Tx Power:-8dBm Min Tx Power:-15dBm Min Rx Sensitivity:-34dBm Link budget:19dBm |
|
Portų skaičius |
JetNet 3810Gf: 8 x 10/100 TX PoE ir 2 x 1000 SFP; JetNet 3810f: 8 x 10/100 TX PoE ir 2 x 100 SFP |
4 x 10/100/1000 TX PoE; 1 x 10/100/1000TX;1 x 100/1000TX SFP |
4 x 10/100Base-TX PoE; 2 x 10/100Base-TX; 1 x RS-232 Console |
4 x 10/100Base-TX PoE; 2 x 100Base-FX; 1 x RS-232 Console |
10 |
PoE technologija |
PoE porto įtampa |
DC 48V |
DC 48V |
DC 48V |
DC 48V |
IEEE 802.3af: 15.4W/per port IEEE 802.3at: 30W/per port |
PoE portai |
15,4 W |
30/15,4 W |
Galinės įrangos klasių nustaytmas, klasės ID 0~3 atitinkančios IEEE802.3af standartą, ir 30W galios suteikimas klasei ID 4. |
Įrangos klasės nustatymas, klasės ID 0~3 atitinka IEEE802.3af standartą, ir 30W galios perdavimas klasei ID 4. |
8 |
Funkcijos |
DIP jungikliai |
- |
|
|
|
|
Pranešimai apie įvykius |
"Sausas" relinis išėjimas su 1A@24V galimybe |
|
1 x 1A @24V "Sausas" relinis išėjimas |
1 x 1A @24V |
4 receipt E-mail accounts with mail server authentication |
Maitinimas |
Vartojama galia |
30W be PoE; 95W su PoE; |
|
8W@50V |
8W@50V (Maksimalus) |
80W @ 75oC, 95% Humidity, DC 48V power input |
Maitinimas |
12~24V |
2 x 12~36V |
DC 24~55V |
DC 24~55V |
DC 48V |
Mechaniniai parametrai |
Išmatavimai |
66(W) x 149(H) x 120.5(D) mm |
144mm (H) x 55 mm (W) x 105mm (D) |
46.5 mm (H) x 147.8 mm (W) x 136 mm (D) be DIN bėgelio |
46.5 mm (H) x 174.8 mm (W) x 136 mm (D) (be DIN bėgelio) |
95 (W) x 127 (D) x 160 (H) w/o DIN Rail clip 95 (W) x 136.2 (D) x 160 (H) w/ DIN Rail clip |
Korpusas |
IP31 apsaugos klasės, aliuminis |
IP31 apsaugos klasės, plieninis ir aliuminis |
IP31 apsaugos klasės, aliuminis |
IP31 apsaugos klasės, aliuminis |
Alluminium |
Montavimas |
DIN bėgelis |
DIN bėgelis |
DIN bėgelis arba ant sienos |
DIN bėgelis arba ant sienos |
Din rail clip |
Aplinka |
Darbo temperatūra |
-25 ~ 60°C |
-40 ~ 75℃ |
-40 ~ 60°C |
-40 ~ 60°C |
-40 ~ 75°C: 80Watts |
Sertifikatai |
Laisvas kritimas |
|
|
|
IEC 60068-2-32 |
|
Vibracija |
|
|
|
IEC 60068-2-6 |
|
Šokas |
|
|
|
IEC 60068-2-27 |
|
EMC |
|
|
|
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11 |
|
EMI |
|
|
|
FCC Class A, EN55022 Class A |
|
Garantija |
5 metai |
5 metai |
5 metai |
5 metai |
5 years |
Valdymas |
"Firmware" atnaujinimas |
|
|
TFTP, lokalus failas ir JetView |
TFTP, vietinis failas ir JetView |
|
SNMP MIB |
|
|
RFC 1213 MIBII, RFC 1493 Bridge MIB, RFC 1757 RMON MIB, RFC 2674 VLAN MIB, RFC 1643 Ethernet like MIB, RFC1215 Trap MIB, RFC 3621 Power Ethernet MIB, Korenix Private MIB |
RFC 1213 MIBII, RFC 1493 Bridge MIB, RFC 1757 RMON MIB, RFC 2674 VLAN MIB, RFC 1643 Ethernet like MIB, RFC1215 Trap MIB, RFC 3621 Power Ethernet MIB, Korenix Private MIB |
MIBII, Bridge MIB, Ethernet-like MIB, VLAN MIB, IGMP MIB, Korenix Private MIB. |
SNMP trap |
|
|
Provides Cold start, Warm start, Port event, Power event, Authentication failure, PoE trap and Korenix private trap for proprietary functions |
Provides Cold start, Warm start, Port event, Power event, Authentication failure, PoE trap and Korenix private trap for proprietary functions |
v1, v2c, v3 with SNMP trap function, trap station up to 4 and can be manually configured the trap server IP address. |
Valdymo saugumas |
|
|
4 priėjimai per WEB, Telne, SNMP valdymo apsauga |
4 priėjimai per WEB, telnet, SNMP valdymo apsauga |
IP address security to prevent unauthorized access |
Valdymo sąsajos |
|
|
SNMP v1, v2c and v3, Web browser, JetView and CLI valdymas |
SNMP v1, v2c and v3, Web browser, JetView ir CLI Valdymas |
Telnet, local RS-232 console, Web- browser interface, SNMP, Trap and SMTP interface. Cisco-Like CLI, Telnet, Web |
|
|
Technologija |
Standartai |
IEEE 802.3 10 Base-T Ethernet; IEEE 802.3u 100 Base-TX Fast Ethernet; IEEE 802.3ab 1000 Base-TX; IEEE 802.3x Flow Control and Back-pressure; IEEE 802.3af Power over Ethernet; IEEE 802.3at High Power over Ethernet; IEEE 802.1AB Link Layer Discovery Protocol (LLDP); IEEE 802.1p Class of Service (CoS); IEEE 802.1Q VLAN and GVRP; IEEE 802.1D-2004 Rapid Spanning Tree Protocol (RSTP); IEEE 802.1s Multiple Spanning Tree Protocol (MSTP); IEEE802.3ad Link Aggregation Protocol (LACP); IEEE802.1x Port Based Network Access Protocol |
Valdymas |
"Firmware" atnaujinimas |
- |
SNMP MIB |
MIBII, Bridge MIB, Ethernet-like MIB, VLAN MIB, IGMP MIB, Korenix Private MIB. |
SNMP trap |
v1, v2c, V3 with SNMP trap function, trap station up to 4 and can be manually configured the trap server IP address. |
Valdymo saugumas |
- |
Valdymo sąsajos |
Telnet, local RS-232 console, Web- browser interface, SNMP, Trap and SMTP interface. Cisco-Like CLI, Telnet, Web, TFTP/Web Update for firmware and configuration backup and restore, DHCP Client, warm reboot, reset to default, Admin password, Port Speed/Duplex Control, status, statistic, MAC address table display, static MAC, Aging time, SNMP v1, v2c, v3, Traps and RMON groups 1,2,3,9 . |
Sąsajos |
Portų skaičius |
10/100 TX port: JetNet 6810G-RJ: 8 x rugged RJ-45 JetNet 6810G-M12: 8 x M12-D-Code 4-pin Female 10/100/1000 TX port: JetNet 6810G-RJ: 2 x rugged IP-67 RJ-45 JetNet 6810G-M12: 2 x M12-A-Code 8-pin Female Console port & Alarm Relay Output: M12 A-code Male for RS-232 and relay alarm output. Power port: CTG-4F 4-pin Rugged IP-67 Connector |
PoE technologija |
PoE portai |
15,4W |
PoE porto įtampa |
DC 48V |
Funkcijos |
Pranešimai apie įvykius |
1 x 1A @24V "Sausas" relinis išėjimas |
Maitinimas |
Maitinimas |
DC 48~57V |
Vartojama galia |
- |
Mechaniniai parametrai |
Montavimas |
DIN bėgelis arba sukamas prie sienos |
Korpusas |
Plieninis ir aliuminis |
Išmatavimai |
JetNet 6810G-M12/ 6810G-RJ : 198 (W) x 145.2 (H) x 74 (D) be montavimo priedų; JetNet 6810G-M12/ 6810G-RJ : 230.6 (W) x 145.2 (H) x 74 (D) su montavimo priedais |
Aplinka |
Darbo temperatūra |
-40°C ~ 60°C |
Sertifikatai |
Garantija |
5 metai |
|